99精品热在线观看视频,无限资源观看大全视频下载,国产精品视频免费一区二区三区,免费视频的软件app推荐,成在人av免费观看高潮,亚洲不卡国产精品,久久99国产麻豆一区二区三区,久久99热成人精品国产

CN
Input signal
Output signal
Channels
Power Supply Mode
The following 35 products are eligible
NPEXA- C1D11L
2 inputs and 2 outputs contrast
Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has loop powered. The input and output is galvanically isolated from each other. Calibrate the apparatus or modify parameters by using a handheld programmer.
NPEXA-C21
1 input and 1 output contrast
Temperature input isolated barrier, it converts the thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
NPEXA-C211
1 input and 2 outputs contrast
Temperature input isolated barrier, it converts the thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
NPEXA-C2D11
2 inputs and 2 outputs contrast
Temperature input isolated barrier, it converts the thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
NPEXA-C21A2
1 input and 3 outputs contrast
Temperature input isolated barrier, it converts the resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation, two relay alarm outputs. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
NPEXA-C21T1
1 input and 2 outputs contrast
Temperature input isolated barrier, it converts the resistance signals from a hazardous area into 4~20mA and RS485 signals to a safe area by isolation. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. Calibrate the apparatus or modify parameters by using a handheld programmer.